Bi-Directional Amplifier (BDA) Comparison Chart
| Product Name | Fiplex DH7S-D-733A - DIGITAL SIGNAL BOOSTER. PS 700 MHz + FirstNet, Single Band +33dBm, Class A, 32 filters + 2 Adj sub band, NFPA, DC. | TruePath - Channelized (Class A) Dual Band 700/800 MHz Public Safety BDA, 2 Watts, DC | Fiplex DH7S-A-7S33A - DIGITAL SIGNAL BOOSTER. PS 800 + 700 MHz + FirstNet, Dual Band +33dBm per band, Class A, 32 filters per band + 2 Adj sub band, NFPA, AC. | PSR-78-9537-U (5W - UL2524 Certified Channelized Digital Repeater for Public Safety - 700/800 MHz) | TruePath - Class B 700 or 800 MHz Public Safety BDA, 2 Watts, AC |
|---|---|---|---|---|---|
| Brand |
|
|
|
|
|
| Supported Bands | 700 | 700/800 Dual-Band , Band 14 | 700/800 Dual-Band | 700 , 800 , 700/800 Dual-Band , Band 14 | 700 , 800 , Band 14 |
| Class | A | A | A | B | B |
| Uplink Frequencies in MHz From | 788 | 788 | 788 & 806 | 799 / 806 | 788 |
| Uplink Frequencies in MHz To | 805 | 824 | 805 & 824 | 805 / 816 | 824 |
| Uplink Frequencies in MHz | From: 788 MHz To: 805 MHz | From: 788 MHz To: 824 MHz | From: 788 & 806 MHz To: 805 & 824 MHz | From: 799 / 806 MHz To: 805 / 816 MHz | From: 788 MHz To: 824 MHz |
| Downlink Frequencies in MHz From | 758 | 758 | 758 & 851 | 769 / 851 | 758 |
| Downlink Frequencies in MHz To | 775 | 896 | 775 & 869 | 775 / 861 | 896 |
| Downlink Frequencies in MHz | From: 758 MHz To: 775 MHz | From: 758 MHz To: 896 MHz | From: 758 & 851 MHz To: 775 & 869 MHz | From: 769 / 851 MHz To: 775 / 861 MHz | From: 758 MHz To: 896 MHz |
| Uplink Composite Power in dBm | 24 dBm | 27 dBm | 24 dBm | 37 dBm | 27 dBm |
| Downlink Composite Power in dBm | 33 dBm | 33 dBm | 33 dBm | 30 dBm | 33 dBm |
| Power Consumption in Watts | 80 Watts | 160 Watts | 80 Watts | 263 Watts | 160 Watts |
| 2524 NRTL for Listed Products | SGS | UL | SGS | UL | UL |
| 2524 Listing Status | Listed | Listed | Listed | Listed | Listed |
| 2524 Certification Date | |||||
| STD 2524 Comments | Investigated to UL2524 - 2nd Edition Revised 2019-02-28, Bi-directional amplifier |
UL 2524 Listed Second Edition UTMH.S36316 - In-building Two-way Emergency Radio Communication Enhancement Systems First Emergency Radio Communication Enhancement System (ERCES) to Receive the Enhanced UL Certification Mark to UL 2524, Second Edition |
Investigated to UL2524 - 2nd Edition Revised 2019-02-28, Bi-directional amplifier | ||
| Other Certifications | FCC, NFPA, Buy American Compliant | CAN/CSA-C22.2 No. 62638-1, FCC Part 20, Part 90 | FCC, NFPA, Buy American Compliant | CAN/CSA-C22.2 No. 62638-1, FCC Part 20 Part90 | |
| Website Link or Product Page | https://fiplex.com/flex-in-building-solution/ | 7831758-0011 | https://fiplex.com/flex-in-building-solution/ | PSR-78-9537-U | 7831851-0001 |
| Notes | www.fiplex.com | Wireless Supply also offers our BDA products as a kit which includes the BBU, annunciator and alarm junction boxes for connection to a buildings fire alarm panel | www.fiplex.com | NFPA / IFC Compliant and UL 2524, second edition, Listed/Certified | Wireless Supply also offers our BDA products as a kit which includes the BBU, annunciator, and alarm junction boxes for connection to the buildings fire alarm panel |
| Organization Name | Honeywell-Fiplex | Wireless Supply, LLC | Honeywell-Fiplex | Advanced RF Technologies (ADRF) - USA | Wireless Supply, LLC |